Vs sup2t 10g datasheet. VS-C6509E-S720-10G Catalyst Chassis+Fan. Vs sup2t 10g datasheet

 
 VS-C6509E-S720-10G Catalyst Chassis+FanVs sup2t 10g datasheet 8 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G SAL16138MPH Mod MAC addresses Hw Fw Sw Status--- ----- ----- ----- ----- 8 588d

Each stack is single supervisor VS-SUP2T-10G. e514. The VS-SUP2T-10G features a new MSFC5 daughterboard with an integrated IBC and a new single, dual-core MPC8572 PPC RP CPU (with ECC-protected L2 and L3 cache, L1 cache is parity detection capable) that operates at 1. 39. Make sure to start with the VSS, both the devices has same model and. e514. Hi everyone, I'm having some difficulty understanding QoS on Sup2T. Product. €5€€€ 5€ Supervisor Engine 2T 10GE w/ CTS (Active)VS-SUP2T-10G€ €€€€ SAL15056BKR Sup2T の場合、Eureka という内部コード名が設定されたレイヤ 2(L2)フォワーディング エン ジン(FE)で ELAM を実行します。L2 FE データ バス(DBUS)に、L2 およびレイヤ4 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G SAL1941QX54 5 48 CEF720 48 port 10/100/1000mb Ethernet WS-X6848-GE-TX SAL1825UZLA. The documentation set for this product strives to use bias-free language. This is a chronological list of the 15. The modules also work in Catalyst 6500 Series Switches. J9538A, J9548A, J9536A. This document is Cisco Public Information. 393. SY3. 6 Policy Feature Card 4 VS-F6K-PFC4 SAL202601AH 3. my supervisor is VS-SUP2T-10G with XL but i am ordering the module WS-X6816-10G-2T which is. The last day to order the affected product(s) is July 31, 2015. Working in conjunction with the Catalyst ® Supervisor Engine 2T/2TXL. (Acti VS-SUP2T-10G SAL1618BM8W 2 16 CEF720 16 port 10GE WS-X6716-10GE SAL16159VEP 4 48 CEF720 48 port 10/100/1000mb Ethernet WS. The VS-SUP2T-10G features a new MSFC5 daughterboard with an integrated IBC and a new single, dual-core MPC8572 PPC RP CPU (with ECC-protected L2 and L3 cache, L1 cache is parity detection capable) that operates at 1. Can I mix a Cisco Supervisor Engine 2T with Sup720-10G in a VSS-configured system? A. Each switch only has one Supervisor module (VS-SUP2T-10G). In VSS mode, unsupported. End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6500 Switch Accessories. VS-S2T-10G. The Future Is 40 Gigabit Ethernet White Paper (PDF - 2 MB) Virtual Private LAN Service on Cisco Catalyst 6500 Supervisor Engine 2T. can you please help me to choose the supervisor engine . Refurbished. Finally, it describes how to attach network interface cables (optical and copper) to the modules. bin. Soon,i have another same 6807(VS-SUP2T-10G*2,C6800-32P10G*2). 7 5 Supervisor Engine 2T 10GE w/ CTS (Hot) VS-SUP2T-10G SAL202801YG. Supervisor Engine 2T 10GE w/ CTS" we used a converter CVR-X2-SFP10G in the core switch and the cable is SFP-H10GB-CU3M However the port is not connected and the led is solid orange . Customers with active service contracts will continue to receive support from the Cisco Technical Assistance Center. %C6KENV-4-MINORTEMPALAR. 5 5 Supervisor Engine 720 10GE (Active) VS-S720-10G SAL1323RSW8. Again, not very familiar with the sup2T, but on a 720 you can specify just a device as part of the boot string, and the boot process will look for any valid image (I believe restricted to the root of the device) and boot it. Cheers, Scott Hodgdon. below is the show inventory on my switch. Mod Sub-Module Model Hw. 1. 3 12. the 6513-VS-SUP2T-10G supervisor engines do support VSS. VS-S2T-10G VS-S2T-10G XL C6800-SUP6T C6800-SUP6T-XL You can also use these 40-GB modules with the Cisco FourX Converter Module 4: WS-X6904-40G-2T WS-X6904-40G-2TXL Cisco 10GBASE Dense Wavelength-Division Multiplexing SFP+ Modules Data Sheet. Latest rcommended IOS s2t54-adventerprisek9-mz. 3 8 DCEF2T 8 port 10GE WS-X6908-10GThe 4-port 10 Gigabit Ethernet fiber module (Figure 4) has no oversubcription and is designed for deployments in which line rate is important. In VSS mode, unsupported switching modules remain powered off. ChiefTeam538. Recommended version is. Cisco Catalyst 6500/6800 Supervisor 6T Architecture White Paper. 2GB for Lite and XL (4GB upgrade with 2GB memory upgrade (2+2) NVRAM. Default Control Plane Policy on Catalyst 6500/Sup2T and Catalyst 6880 Configuration Example ;VS-S2T-10G= Cat 6500 Sup 2T with 2 x 10GbE and 3 x 1GbE with MSFC5 PFC4 - S-65-S720= WS-SUP720-3B w/512MB and 512PCMCIA . It works fine but ACL and route-map counters not incrementing. Consider switching to something new: The Cisco Catalyst 9400 Series Switches offer greater speed, performance and security. Labels: Labels: Wireless LAN Controller; 0 Helpful Share Reply. The VS-S2T-10G is only compatible with the E series chassis so you cannot use it without a chassis upgrade: The WS-SUP720-3B would work, or you could use the VS-S720-10G-3C if you need 10gb ports on the supervisor card. Mod MAC addresses Hw Fw Sw Status. UDI=VS-SUP2T-10G:SALxxxxxxxx there is no service impact and we won't be fixing it for now. 98 x 14. In VSS mode, unsupported switching modules remain powered off. I have this problem too. 2(1)SY1. Attache. Cisco Nexus 7000 Series Supervisor2 Module. We have purchased an additional SUP module to install into each switch so that we can create a quad SUP VSS. 2+ VSS mode support as shown in the Release. Looking for verification which one (or maybe both) is compatible so when we replace VS-SUP2T-10G with e. Is the following upgrade process correct? 1. 02. Although not mandatory, we recommend that you install a second 2-GB DRAM module when installing VS-F6K-PFC4XL=. Product Description. 0. Note that the L2 FE Data Bus (DBUS) contains original header information before the L2 and Layer 3 (L3) lookups, and the Result Bus (RBUS). C6880-X-SUP. Compatibility matrix which eludes the CVR-X2-SFP10G module is compatible with the VS-S2T-10G and SFP-H10GB-CU5M but only if the SFP-H10GB-CU5M is version 2. 7 5 Supervisor Engine 2T 10GE w/ CTS (Hot) VS-SUP2T-10G SAL202801YG. 2(18r)S1 15. 136 W. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. VS-C6513E-SUP2T. VSS mode does not support 61xx switching modules. We only have VS-SUP2T-10G and C6800-32P10 in our VSS. LTB Date. Switch Number: 101 Role: FEX----- ----- Mod Ports Card Type Model Serial No. Check if the commands needed are available. g. It also features a new, separate, out-of-band Connectivity Management Processor (CMP) CPU. 150-1. Certified for operation: 0 to 6500 feet (0 to 2000 m) Working in conjunction with the Catalyst ® 6500-E/6807-XL Supervisor Engine 2T/2TXL (VS-S2T-10G & VS-S2T-10GXL), they can serve different needs on campus deployments. The two supervisor engines must match exactly. The ports are Gi1/5/3 and Gi2/5/3. Current version is. bin. 56. VS-SUP2T-10G= Sup2T Baseboard spare: There is no replacement product available. VSS . Up to 25. bin. The autoqos feature works for some ports but does not work on port-channel interfaces. my question is that if this is the correct behavior on 6500 ??. 46W from on 6000W power supply. 0021 2. And Cisco proposed the 2 substitutes written above: vs-s2t-10g= and vs-s2t-10g-xl=. Cisco 7606S Chassis,6-slot, VS-S2T-10G-XL,PS. We. 10/31/2014. Solved! Go to Solution. My First question is Can i configure VSS with this switches, as some documents say should require (Virtual Switching Supervisor 720-10GE (VS-S720-10GE-3C and VS-S720-10GE-3CXL) Secondly if yes can i use only one 10G link as VSL between two switches. Reseating usually helps to recover this condition in case of transient failures but. VS-SUP2T-10G Catalyst 6500 Supervisor Engine 2T Baseboard VS-F6K-PFC4 Cat 6k 80G Sys Daughter Board Sup2T PFC4 MEM-SUP2T-2GB Catalyst 6500. Product Migration Options. 07-29-2020 08:49 AM. 0(1)SY7a ) with VS-SUP2T-10G. VS-S720-10G: Cat 6500 Supervisor 720 with 2 x 10GbE. 36 A; VS-S2T-10G-XL—10. Sup2T 1Gig port transceivers/SFPs not detected causing link up failures. This bypasses the need for a spare. can we install new C6800-8P10G= Interface Module during switch power ON (during working condition), or. Find Cisco VS-S2T-10G-XL best price and specification, and more Cisco Catalyst 6500 Series Bundle: VS-S2T-10G-XL, delivering high speed and reliable network connections for you need. The password-recovery process will only work if the line card works stand alone. There's a Catalyst 6506E chassis. $149. 00. 40-port 50G/25G/10G (SFP56) and 2-port 400G (QSFP-DD) and 2-port 200G (QSFP56) with C9600X-SUP-2. With the 1-Gigabit Ethernet ports disabled, the QoS port architecture of the 10-Gigabit Ethernet ports is 8q4t/1p7q4t. We got 1x c6509-E and 1x 68707XL. Labels: Labels: Other Switching; 0 Helpful Reply. 00 1. VS-C6509E-S720-10G Catalyst Chassis+Fan Tray+Sup720-10G; IP Cisco Catalyst 6500/6800 Supervisor 6T Architecture White Paper. Cat 6500 Sup 2T with 2 x 10GbE and 3 x 1GbE with MSFC5 PFC4. Customers with active service contracts will continue to receive support from the Cisco Technical Assistance Center (TAC) as shown in Table 1 of the EoL bulletin. The versatile Cisco Catalyst 6500-E Series Chassis is ideal for addressing high-performance, high- port-density Fast Ethernet, Gigabit Ethernet, and 10 and 40 Gigabit Ethernet applications in all parts of the. Product Overview. View the benefits of upgrading >. Free PDF of Cisco VS-S2T-10G. module 7 asic-5 temperature: 54C. 2(50r)SYL 15. 5 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G SAL1741E42N. 3 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G 4 5 Supervisor Engine 2T 10GE w/ CTS (CSSO VS-SUP2T-10G. Name VS-S2T-10G VS-S2T-10G-XL IPv4 routing In hardware Up to 720 Mpps ** In hardware Up to 720 Mpps ** IPv6 routing In hardware Up to 390 Mpps ** In hardware Up to 390 Mpps ** L2 bridging In hardware Up to 720 Mpps ** In hardware Up to 720 Mpps ** MPLS MPLS in hardware to enable use of Layer 3 VPNs and EoMPLS tunneling. 2 Ok. When your line card has the DFC4-A installed IT. g. The Cisco Nexus 93108TC-FX3P Switch (Figure 2) is a compact 1 RU switch that supports 2. Page 2 of 22 Contents IntroductionVS-S2T-10G= Cat 6500 Sup 2T with 2 x 10GbE and 3 x 1GbE with MSFC5 PFC4-S-65-S720= WS-SUP720-3B w/512MB and 512PCMCIA. Either two VS-SUP2T-10G or two VS-SUP2T-10G-XL supervisor engines. $88,000. Operating altitude. A leader in scalability and flexibility, this product family is designed for use. Cisco Supervisor Engine 2T-10GE (model number VS-S2T-10G-XL)—Shipped with factory-installed Policy Feature Card 4XL. This document is Cisco Public Information. Mod MAC addresses Hw Fw Sw Status--- ----- ----- ----- ----- ----- 1 1cdf. I have 3 pairs of 6807 VSS switches. VSS. End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6500 Switch Accessories 03-Aug-2020. BOM. 652); SFP-10G-LR, supports 10 km on standard single-mode fiber (SMF, G. you can run a show mod and you will see the serial numbers for the modules are different than the chassis. Could you explain the difference? Regards, SK. Doc Preview. 0(1)SY2 Ok. In response to Leo Laohoo. Aruba 8320 48p 10G SFP/SFP⁠+ and 6p 40G QSFP⁠+ Switch. VS-S2T-10G | The Cisco Catalyst 6500 Series is the flagship among switching platforms. 7. we are planning to install C6800-8P10G= Interface Module on our WS-C6509-E (two switches configured on VSS). We are currently using the SUP720-3B and using the 1G SFPs on board. Table 1. module 7 asic-5 temperature: 54C. Has anyone actually used all. It has exceeded normal operating temperature range. Platform scalability: Delivering up to 80 Gbps per slot of switching capacity on E-Series chassis; 2-Terabit aggregate bandwidth capacity using the 6513-E chassis, scaling to 4-Terabit capacity with VSS. *Sep 30 02:06:26. VS-S720-10G-3C . Mod MAC addresses Hw Fw Sw Status. VS-S2T-10G . . I installed Sup2T engine on 7606-x chassis. 11 slot chassis * 160 Gbps= 1760 i. VS-S720-10G-3C= Cat 6500 Supervisor 720 with 2 x 10GbE and 3x1GE MSFC3 PFC3C - VS-C6513-S720-10G . Hall of Fame. 1x and 802. 0 (1)SY2, supervisor- VS-SUP2T-10G) kindly help us to understand following. Can you let me know if the following kit list will support the 6148 line card in VSS configuration - Cards and Modules 1. 40. How many ports do i lose when enabling performance mode. Catalyst 6506-E Switch: Access product specifications, documents, downloads, Visio stencils, product images, and community. The entire process is pretty straight forward. Hello, I have a 6506E chassis that I am upgrading to a pair of SUP2Ts. 40. 07. (There were two variants of this supervisor, one having dual 10G links [enough to saturate the classic bus]. That's because although your OP asked about a 6708, your installed card in a 6908. 1 (2)SY6. Cisco annonce la date d’arrêt de commercialisation et de fin de vie de Cisco Catalyst 6506-E, Catalyst 6509-E, Catalyst 6509-V-E, Catalyst 6513-E, VS-S2T-10G, VS-S2T-10G-XL, Bundles and accessories. There is two SUP2T-10G. Options. EOS/EOL for 64MB Compact Flash for Cisco Catalyst 6500. It supports 80 Gbps with your sup2T. Both of the chassis are up on Cisco IOS Software Release 15. Sup Engine : VS-SUP-2T-10G. You can also save your config to a tftp server and. The link below gets you started:i have a Cisco 6504E with a VS-S2T-10G and a small problems with two card: *Mar 25 17:20:06. The Cisco Catalyst 6509-E supports Cisco Catalyst 6500 Series end-to. The Cisco Catalyst ® 6500 Series Switches offer a variety of 10 Gigabit and Gigabit Ethernet modules which work in conjunction with the new Catalyst 6500 Supervisor Engine 2T/2TXL (VS-S2T-10G & VS-S2T-10GXL) to serve different needs in the campus and data center for enterprise, commercial, and service provider customers. 2(50r)SYS 15. 150-1. 1(2)SY15—20 August 2019 • Release 15. Beginner. SY6. 5 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G SAL1643R24T. 0(1)SY2 OkUDI=VS-SUP2T-10G:SAL1813P748. IPv4 unicast takes 1 entry, IPv6 unicast takes 2 entries, IPv4 multicast takes 2 entries, IPv6 multicast takes 4 entries. EOS/EOL for 64MB Compact. Does anyone know how to enable it? comments sorted by Best Top New Controversial Q&A Add a Comment blacksheep5405 • Additional comment actions. Helping empower AI learning through affordability. CMP should be treated as a separate entity and there is no replication of such information between supervisors. . I recall, the only 67xx card that will not work with a sup2T is the 6708, because it comes with a DFC3 that cannot be replaced (with the DFC4 or a CFC). 44. But in the solt 1 the chassis only detects the 40G. Both switches need to run the same IOS version (check with 'sh ver'). 00. VS-S2T-10G. Find answers to your questions by entering keywords or phrases in the Search bar above. 60. (Acti VS-SUP2T-10G SAL1552Z77B 6 5 Supervisor Engine 2T 10GE w/ CTS (Hot) VS-SUP2T-10G SAL1551YMH0. Cisco announces the end-of-sale and end-of-life dates for the Cisco Catalyst 6506-E, Catalyst 6509-E, Catalyst 6509-V-E, Catalyst 6513-E, VS-S2T-10G, VS-S2T-10G-XL, Bundles and accessories. 12 150. Data Sheet and Installation Notes. Uplink ports (PORT 1 through PORT 5) ·Supervisor Engine 2T has five uplink ports: ·Two 10GBASE-X ports·Three 1000BASE-X ports·Each uplink port has a link LED associated with it. $53,995. 07-14-2017 08:12 PM. I am trying to apply queueing configuration on the interface but failed. Itprice. So, I think, the Q&A is correct. There's also a VS-SUP2T supervisor card. 27% 0 IP NAT Ager. 1445. Logos remain the. Installing SUP2T in a 6807-XL chassis boosts backplane speed from 80 Gbps of an E-Chassis up to 220 Gbps, although this is nowhere near the chassis maximum capacity of 880 Gbps. 94. 11-17-2016 05:43 AM - edited ‎03-08-2019 08:11 AM. Solved: Hi, We've just invested in a pair of Sup2Ts to upgrade a Sup720 6509 chassis but I'm unsure exactly how the management port (s), aka the Connectivity Management Processor (CMP), should be configured (and. 05-14-2013 03:09 PM. 70 60. The Cisco® Catalyst® 6500 Supervisor Engine 2T is the newest addition to the family of supervisor engines. Cisco Catalyst 9606R chassis is hardware ready to support up to 25. Execute the conversion command, which will reboot the switches. After replacing it, load the same IOS as the old sup to the flash and than copy and paste the old config to the new sup from the console. As part of the upgrade the two chassis will be converted to VSS. 4 48 CEF720 48 port 10/100/1000mb Ethernet WS-X6848-GE-TX SAL19038DU0. Scott Fella. I am not seeing compatibility of the Sup2T with the IDSM2 in the release notes. Beginner Options. 7 48 CEF720 48 port 10/100/1000mb. 2 OkVS-SUP2T-10G が稼動する Catalyst 6500 シリーズスイッチではライセンスのインストールは必要ありませんが、同様な実装の他の機器と異なり、以下の様に、'show license' コマンドが入力でき出力も表示されます。 この動作は不具合ではありませんので、出力等に関して調査を行う必要はありません。5 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G SAL17194J7J. 1344. Depending on the sizes of the frames making up the incoming traffic, the actual enforced level might differ from the configured. Which alternative card should I take for this EOL linecard, or can I use the proposed linecard (use extra daughtercard DFC4)?Symptom: Cat6500 %LICENSE-6-RECOVERED message output when reload device. Cisco Catalyst 6500 Series Supervisor Engine 720-10G-3C Cisco Catalyst 6500 Series Supervisor Engine 720-10G-3CXL Cisco Catalyst 6500 Series Supervisor Engine 2T Power Supply Compatibility * Indicates EoS Power Supply AC: 2500W*, 3000W, 4000W, 6000W, 8700W DC: 2500W, 4000W, 6000W Module Compatibility All modules based on the software release in. Would anyone be able to confirm that the below line card works with our T2 supervisors? The original ones WS-X6704-10GE= are end of life and can no longer be ordered. Feature VS-S2T-10G VS-S2T-10G-XL Port security Yes Yes IEEE 802. I reviewed the original boot-up process and I can see that the line card is booting up as "Standby". Options. Caveats Resolved in Catalyst 6500 Supervisor Engine 2T ROMMON Software Release 12. 1(2)SY11 Ok1 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G SAL1618BM8W 2 16 CEF720 16 port 10GE WS-X6716-10GE SAL16159VEP. com is neither a partner nor an affiliate of Cisco, Huawei and Fortinet. However, from the second link I see a limit of 256K IPv4 routes for SUP2T and PFC4, instead SUP2T XL and PFC4 XL can support. Les clients ont jusqu'au 30 octobre 2020 pour commander les produits concernés. Community. -VS-S2T-10G-XL= Cat 6500 Sup 2T with 2x10GbE and 3 x 1GbE with MSFC5 PFC4XL: C6800-SUP6T-XL= Catalyst 6800 Sup6T (440G/slot) with 8x10GE, 2x40GE (XL) MEM-SUP2T-4GB: 4G DRAM Memory Total for Sup2T and Sup2TXL (2G + 2G) -. Cisco announces the end-of-sale and end-of life dates for the Cisco Catalyst 6500 Series Supervisor Engine 32, plus the Cisco Catalyst 6500 and Cisco 7600 Series Supervisor Engine 32 Bundles. Chinese; EN US; French; Japanese; Korean; PortugueseThese are based on the Supervisor Engine 2T and the Supervisor Engine 720-10G. 3 CPU Daughterboard VS-F6K-MSFC5 xxxxxxxxxxx 3. 5 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G SAL1817R0YH 6 5 Supervisor Engine 2T 10GE w/ CTS (Hot) VS-SUP2T-10G SAL1815PZPK. 44 550. 10. 18 191. BOM. 54 10. We reboot after changing the boot commandManufactured by Cisco. Le centre d’assistance technique de Cisco (TAC) continuera de prendre en charge les clients dont les contrats. Figure 4. Hi, I have two vs-c6509E-SUP2T switches. 711: %DOSFS-5-DIR_ENTRY_CORRUPTION: licdisk:1: has. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. 2 8 DCEF2T 8 port 10GE. VS-SUP-2T-10G. VS-SUP2T-10G. Explore our database of over. Hey I need the procedure for replacing a failed vs-sup2t-10g in a 6807-xl chassis. 0 (1)SY1. I am running into these errors below. Catalyst 6503-E Switch: Access product specifications, documents, downloads, Visio stencils, product images, and community. VS. Price Trend of VS-S2T-10G. Note that the L2 FE data bus (DBUS) contains original header information before the L2 and L3 lookup and the result bus (RBUS) contains the results. 43% 4. VS-SUP2T-10G-PFC4XL Supervisor Engine 2T with PFC4XL daughter card. 0 Ok 5 Distributed Forwarding Card WS-F6K-DFC4-A SAL1930L1G8 2. ROM: System Bootstrap, Version 12. If you have a monitoring system e. 6 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G SAL202900NU 7 24 CEF720 24 port 1000mb SFP WS-X6724-SFP SAL12351Y57. The Cisco Nexus 7700 Supervisor 2E Module is based on a two-quad-core Intel Xeon processor with 32 GB of memory that scales the control plane by harnessing the flexibility and power of the two quad cores, offering high control-plane performance and scalability: for example, support for more virtual device contexts (VDCs) and fabric. which. Our super fast turnaround times and high quality stock located all. 56. Greetings, I do not know if this is already a thread in the forum, but I have been searching for it and did not find it. For the Sup2T, we want to perform the ELAM on the L2 forwarding engine (FE) with internal codename Eureka. 0f9c. Configure the virtual switch links. Price Alert. However this card seems not to be supported by the SUP2T-10G supervisor. 04-16-2017 08:35 AM. *May 27 06:47:53. 5 MSFC3 Daughterboard VS-F6K-MSFC3 SAL1316NK30 1. We are ready to help with your network equipment and services needs. Cat 6500 Supervisor 720 with 2 x 10GbE and 3x1GE MSFC3 PFC3C - WS-SUP720-3B= Catalyst 6500/Cisco 7600 Supervisor 720 Fabric MSFC3 PFC3B . 1. 4 Ok 7 Distributed Forwarding Card WS-F6K-DFC4-A SAL1927JC3V. Catalyst 9300X 10G, 25G, 40G, mGig and 100G Catalyst 9300 Stackwise-1T (480G when stacking with Catalyst 9300 model) 48x 10G (Larger Power Budget) Up to 100G IPsec* (2x hosting resources over models) Catalyst 9300 10G, 25G, 40G and mGig Stackwise-480 48x5G and 24x10G Catalyst 9300L Stackwise-320 12x10GI am preparing to do an upgrade from Sup720 to Sup2T on a Catalyst 6509E. Supervisor Engine 2T integrates a high-performance 2-Terabit crossbar switch fabric that enables 80 Gbps switching capacity per slot on all Cisco Cataly. 15. EOS/EOL for 64MB Compact. hello, i have ordered VS-S2T-10G-XL but when i am doing a show invetory it is showing it as VS-SUP2T-10G. 5 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G 6 5 Supervisor Engine 2T 10GE w/ CTS (Hot) VS-SUP2T-10G . all non-XL or all XL. Everything work fine. Recently got a 6504-E. 191. C6880-X-LE-16P10G. Hello community, Hi have a Cisco Catalyst 6807-XL and some line cards as supervisor VS-SUP2T-10G, a module C6800-32P10G, a module. 0 Helpful. JL479A. 155-1. North South University. 00. VS-SUP2T-10G Catalyst 6500 Supervisor Engine 2T Baseboard. 151-2. End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6500 Switch Accessories 03-Aug-2020. The CISCO Catalyst VS-SUP2T-10G VS-F6K-PFC4 represents one item of our extensive telecommunications portfolio, which includes products from many of the world’s key OEM’s, including Ericsson, Siemens, Nortel, Nokia and Marconi. EN US. Cisco 7613. VS-C6513E-SUP2T5 5 Supervisor Engine 2T 10GE w/ CTS (Active)VS-SUP2T-10G SAL15056BKR. Free PDF of Cisco VS-S2T-10G-XL. Catalyst Chassis+Fan Tray+Sup720-10G; IP Base ONLY incl. MSFC3. Hello all experts! No matter how I search on the internet about "VS-SUP2T-10G", there was no datasheet. 2(1)SY5, supervisor- VS-SUP2T-10G, VSS running) we are planning to install C6800-8P10G Interface Module. On the 1st chassis I upgraded we had no problems and so I "borrowed" a known working SUP2T and tried it in that. Note these both require the High Speed Fan and a 2500 watt power supply. The four Supervisor Engine Model Numbers supporting VSS are: VS-S2T-10G VS-S2T-10G-XL VS-S720-10G-3C VS-S720-10G-3CXL Table 1. Match clauses: ip address (access-lists): AMP_HTTP_TRAFFIC1. Cat 6500 Supervisor 720 with 2 ports 10GbE MSFC3 PFC3C --Sweta *Rate and mark the helpful answers. Only WS-X6904-40G-2T is being replaced and not the C6800-32P10G module. Equipped with a high performance processor, the MSFC runs layer 2 protocols on one CPU and layer 3 protocols on the second CPU. Leo Laohoo. 1SY OL-20679-01 Hierarchical List of Releases • See the “Hierarchical List of Releases” section on page 3 for information about parent releases. Up to 25. 5(1)SY OL-20679-01 Chronological List of Releases † New Features in Release 15. 2(50r)SYS 15. In response to hashknife. 375: %C6KENV-2-DFCMISMATCH: Module 2 DFC incompatible with Supervisor DFC. Supervisor Engine 2T integrates a high-performance 2-Terabit crossbar switch fabric that enables 80 Gbps switching capacity per slot on all Cisco Catalyst 6500 E-Series Chassis. what is the IOS code running, Try below syntax : logging origin-id string <device_hostname>. The high cpu usage by interrupts is the signal that many traffic flows are process switched in your C6509 instead of being processed by CEF. Options. 41 x 1. We need to replace a VS-SUP2T-10G supervisor engine in a WS-C6509-E. . One of them is a supervisor module called Supervisor 2T (products VS-S2T-10G and VS-S2T-10G-XL) which practically replaces the previous Sup720 family variants. Other Languages. module 7 asic-1 temperature: 68C. The Future Is 40 Gigabit Ethernet White Paper (PDF - 2 MB) Virtual Private LAN Service on Cisco Catalyst 6500 Supervisor Engine 2T. 0. In much of the documentation, it is stated that Sup2T support MCQ style QoS configurations (using class-map and policy-map) vs older mls configs. Either two VS-SUP2T-10G or two VS-SUP2T-10G-XL supervisor engines. EOS/EOL for 64MB Compact Flash for Cisco Catalyst 6500 Supervisor Engine 720/32. About this product. 66. the VS-SUP2T-10G. Chassis+Fan Tray+ Sup2T+2xPower Supply; IP Services ONLY. Catalyst 6500 Sup2T; VS-S2T-10G; Cisco VS-S2T-10G. 15. 18. A Bridge Connecting IT Hardware to The World Routers. Contact Cisco. It provides up to 34 10 Gigabit Ethernet ports in a single Cisco Catalyst 6509 chassis and 68 10 Gigabit Ethernet ports in a VSS. I dont get any status lights or anything. EOS & EOL: Select Cisco Catalyst 6500 Series Components-Updated 03/Aug/2005. The bundle comes with 2 P/S's. Sup2T is totally different from Sup2. No ratings or reviews yet No ratings or reviews yet. 08-05-2012 07:57 PM.